COLOUR. PROTECTION. POSSIBILITY.

EXPERT ADVICE · 0800 222 423
Hydroclad

Hydroclad

An acrylic / butadiene copolymer waterproofing coating.

Coverage
4m²/ltr for 130µ Dry Film Thickness (DFT)
Recoat
4 hours
Pack Sizes
5ltr & 20ltr

Contact DEKRO for pricing and availability.

Uses & properties

Where this product works.

Hydroclad is a self-cleaning, highly durable, copolymer based coating which cures to form a
tightly adherent, decorative weatherproof membrane. As a waterborne- system, it is free from
strong odour and toxic risk and may be cleaned with using only water on brushes and spray
equipment. The Hydroclad membrane will tolerate thermal movement in the substrate without
splitting or cracking and will retain its elastomeric properties even after prolonged exposure to
ultra-violet light. Hydroclad’s chemical and pollution- resistant surface has been specially
engineered to shed dirt, ensuring it retains a bright, attractive appearance throughout its life.
It’ s vapour permeable and allows entrapped substrate moisture to escape without causing
blistering or delamination. It may be reinforced with chopped strand matt and is capable of
bridging cracks or joints between different substrates. Finally, it produces an effective barrier
to carbon dioxide diffusion and therefore provides reinforced concrete with an excellent
defence against harmful effects of carbonation.

Product system guidance

Preparation and application.

Follow the product datasheet for the complete coating system and application requirements.

Read the product datasheet ↗
Application instructions

Correct surface preparation is essential for good product performance and all surfaces should
be prepared as per the standard Dekro Preparation Specifications. C opies of these are
available on request from your Dekro Paints or can be downloaded from our website –
www.dekro.co.za.
Do not apply when ambient temperatures are < 4°C or > 40°C.
After correct surface preparation, prime with the recommended primer, then stir thoroughly and
apply a minimum of 2 coats of Hydro clad by brush, roller or spray at the specified spread rate.
Allow to dry between coats as per technical data.

Important product notes

IMPORTANT: Walls (cement plaster, concrete or masonry) must be dry before painting and
should not exceed a moisture content of 10% as measured with a Protimeter Surveymaster
Moisture Meter or equal. The ambient temperature must be between 4 ºC and 40 ºC and
humidity between 10% and 85%.
Excessive application thickness and/or rapid drying could lead to mud cracking.
Avoid applying under adverse weather conditions as this could result in poor product
performance.
Work from corner to corner, or from a natural cut off point to another.
Do not attempt touch ups, but redo complete panels.
Always keep a wet edge and avoid downing tools during the application process to prevent lap
marks and variances in colour or texture.
To ensure consistent appearance ensure that the batch numbers on all containers used are
the same. Where batch numbers on containers differ, intermix containers before use.

Safety information

Always keep out of reach of children and animals.
Wear a suitable dust mask and goggles when preparing surfaces.
Ensure good ventilation during application and drying.
If accidental contact with skin, wash immediately with soap and water or a recognised skin
cleaner.
If accidental contact with eyes, rinse immediately with plenty of water and seek medical
advice.
Harmful if swallowed. Seek medical attention and do not induce vomiting.

Storage

use with water. Close containers tightly after use and store in a cool well -ventilated area.

Disposal

Do not empty contents or wash water into drains or water courses.
When disposing please follow local authorities regulations and recycle the container after use.

Technical data

Core specifications at a glance.

Binder type
Acrylic / Butadiene copolymer.
Gloss level
Satin Sheen
Overcoating interval
4 hours
Drying process
Water evaporation followed by coalescence
Viscosity
140ku
Specific gravity
1,2 ±0,05kg/ltr
Coverage / spreading rate
4m²/ltr for 130µ Dry Film Thickness (DFT)
Equipment cleaning
Water
Datasheet colour range
White and special colours on request.
Datasheet pack sizes
5ltr & 20ltr
Application methods
brush, roller or spray
Coats
minimum of 2 coats

A little planning. A better finish.

How much paint
will you need?

Estimate your paint for Hydroclad. Just enter the total surface area you plan to paint.

2 coats4 m² per litre, per coat

Published coverage: 4m²/ltr for 130µ Dry Film Thickness (DFT)

Default: two coats. Check the datasheet for the required coating system.

Use the actual surface area to be coated. For walls, exclude doors and windows; for roofs, allow for the slope and profile.

Your paint estimate

— litres

Enter your surface area to get started.

Uses this product’s published spread rate for the selected number of coats.

A guide, not a guarantee. This estimate uses your selected number of coats (two by default). Actual paint required will vary with surface texture, porosity and condition, preparation, colour changes, application method and wastage. Rough, profiled or absorbent surfaces may need more paint. Published coverage may depend on the specified dry film thickness. Estimate each primer, undercoat and finish separately. Follow the product datasheet and round up to suitable pack sizes; no extra allowance for wastage is included.

DEKRO AI advisor

Ask about Hydroclad.

This advisor knows which product you are viewing. Ask about its coverage, preparation, application or datasheet.

For site-specific requirements, confirm the current datasheet or call 0800 222 423.