COLOUR. PROTECTION. POSSIBILITY.

EXPERT ADVICE · 0800 222 423
Product range packaging

Fibre Reinforced

An economical water based fibre reinforced acrylic, developed for sealing weather -facing and hairline cracked plastered walls to prevent the ingress of moisture. Dries to a matt, finely textured surface.

Coverage
2 - 3m²/litre/coat
Recoat
>6 hours
Pack Sizes
5 litre, 20 litre
Price range: R459,60 through R1 729,36 incl. VAT

Uses & properties

Where this product works.

Recommended for exterior surfaces.
Used as an intermediate, high-build coating for bridging hairline cracks on exposed plastered surfaces.
Suitable for weatherproofing the tops of exposed plastered walls, window sills, small ledges as well as
exposed weather facing walls or fairfaced brick walls.
Please note that Fibre Reinforced is an intermediate coating and should be overcoated with a suitable
waterproofing finishing coat.
Not suitable for the treatment of rising damp as the moisture will collect behind the film and slowly cause
the film to delaminate.

Product system guidance

Preparation and application.

Follow the product datasheet for the complete coating system and application requirements.

Read the product datasheet ↗
Application instructions

Thoroughly stir and apply one coat of Fibre Reinforced to prepared surface using a brush or roller at the
stipulated spread rates. Allow to dry before overcoating. Two coats may be required in very severe
situations.
Fibre Reinforced is a thick, high-build coating and it is essential that it is fully dried before overcoating.
Correct surface preparation is essential for good product performance and all surfaces should be prepared
as per the standard Dekro Preparation Specifications. Copies of these are available on request from Dekro
Paints or can be downloaded from our website – www.dekro.co.za.
OVERCOATING TIME
>6 hours
NOTE: It is essential to adhere to overcoating times, as specified for our various products. Prevailing
weather conditions must be taken into account as ambient and substrate temperatures, humidity and wind,
etc, will influence drying time. Performance problems can occur if any of the previous coats have not been
allowed to dry properly before being overcoated.
IMPORTANT: To prevent surface contamination coatings must not be left longer than 48 hours between
coats. If environmental or weather conditions have caused surface contamination, all surfaces must be
thoroughly washed down before applying the next coati ng.

Important product notes

IMPORTANT: Walls (cement plaster, concrete or masonry) must be dry before painting and should not
exceed a moisture content of 10% as measured with a Protimeter Surveymaster Moisture Meter or equal.
The ambient temperature must not be below 10ºC and not higher than 35ºC.
Humidity must not be below 10% and not higher than 85%.
Excessive application thickness and/or rapid drying could lead to mud cracking.
Do not apply to exterior surfaces in rain, mist or late in the day where there is a possibility of dew.
Do not thin the product unless specifically specified.
Do not attempt touch ups, but redo complete panels.
To ensure consistent appearance ensure that the batch numbers on all containers used are the same.
Where batch numbers on containers differ, intermix containers before use.

Safety information

Always keep out of reach of children and animals.
Wear a suitable dust mask and goggles when preparing surfaces.
Ensure good ventilation during application and drying.
If accidental contact with skin, wash immediately with soap and water or a recognised skin cleaner.
If accidental contact with eyes, rinse immediately with plenty of water and seek medical advice.
Harmful if swallowed. Seek medical attention and do not induce vomiting.

Storage

Close containers tightly after use and store in a cool well -ventilated area.
Avoid storing in direct sunlight and heat.

Disposal

Do not empty contents or wash into drains or water courses.
When disposing please follow local authorities’ regulations and recycle the container after use.

Technical data

Core specifications at a glance.

Binder type
Styrene acrylic co-polymer
Surface dry
<1 hour
Hard dry
<6 hours
Overcoating interval
>6 hours
Drying process
Water evaporation followed by coalescence
Viscosity
115 – 120pp
Specific gravity
1,46 ±0,05kg/litre
Mass non-volatile content
63% ±3%
Volume solids
45% ±3%
Coverage / spreading rate
2 - 3m²/litre/coat
Dry film thickness
180 microns @ 2,5m²/litre
Equipment cleaning
Water
Datasheet colour range
Off White/Light Grey
Datasheet pack sizes
5 litre, 20 litre

A little planning. A better finish.

How much paint
will you need?

Estimate your paint for Fibre Reinforced. Just enter the total surface area you plan to paint.

2 coats2–3 m² per litre, per coat

Published coverage: 2 - 3m²/litre/coat

Default: two coats. Check the datasheet for the required coating system.

Use the actual surface area to be coated. For walls, exclude doors and windows; for roofs, allow for the slope and profile.

Your paint estimate

— litres

Enter your surface area to get started.

Uses this product’s published spread rate for the selected number of coats.

A guide, not a guarantee. This estimate uses your selected number of coats (two by default). Actual paint required will vary with surface texture, porosity and condition, preparation, colour changes, application method and wastage. Rough, profiled or absorbent surfaces may need more paint. Published coverage may depend on the specified dry film thickness. Estimate each primer, undercoat and finish separately. Follow the product datasheet and round up to suitable pack sizes; no extra allowance for wastage is included.

DEKRO AI advisor

Ask about Fibre Reinforced.

This advisor knows which product you are viewing. Ask about its coverage, preparation, application or datasheet.

For site-specific requirements, confirm the current datasheet or call 0800 222 423.